Ge Dryer Not Starting

- 20.45

GE, Hotpoint & RCA Dryer - Not starting, Knob and switch repair ...
photo src: www.youtube.com

A thermal cutoff is an electrical safety device that interrupts electric current when heated to a specific temperature. These devices may be for one-time use or may be reset manually or automatically.


GE, Hotpoint, RCA - Dryer Diagnostic - Not starting - Control ...
photo src: www.youtube.com


Maps, Directions, and Place Reviews



Thermal fuse

A thermal fuse is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.

One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature.

Thermal fuses are usually found in heat-producing electrical appliances such as coffeemakers and hair dryers. They function as safety devices to disconnect the current to the heating element in case of a malfunction (such as a defective thermostat) that would otherwise allow the temperature to rise to dangerous levels, possibly starting a fire.

Unlike electrical fuses or circuit breakers, thermal fuses only react to excessive temperature and not to excessive current (unless the excessive current is sufficient to cause the thermal fuse itself to heat up to the trigger temperature). For example, in a surge protector thermal fuses may be wired in series with the varistors; when the varistors conduct, the fuse heats up and disconnects the power, which eliminates the risk of fire which can occur when the varistors are overloaded.


Ge Dryer Not Starting Video



Thermal switch

A thermal switch (sometimes thermal reset or thermal cutout (TCO)) is a device which normally opens at a high temperature (often with a faint "plink" sound) and re-closes when the temperature drops. The thermal switch may be a bimetallic strip, often encased in a tubular glass bulb to protect it from dust or short circuit. Another common design uses a bimetallic shallow dome-shaped cap which "clicks" to an inside-out inverted cap shape when heated, such as the "Klixon" brand of thermal cutouts.

Unlike a thermal fuse, a thermal switch is usually reusable, and is therefore suited to protecting against temporary situations which are common and user-correctable. Thermal switches are used in power supplies in case of overload, and also as thermostats in some heating and cooling systems.

Another type of thermal switch is a PTC (Positive Temperature Coefficient) thermistor; these thermistors have a "switch" temperature at which the resistance suddenly rises rapidly, limiting the current through the circuit. When used in conjunction with a thermistor relay, the PTC will switch off an electrical system at a desired temperature. Typical use is for motor overheat protection.

Thermal switches are included in some light fixtures, particularly with recessed lights, where excessive heat is most likely to occur. This may lead to "cycling", where a light turns off and back on every few minutes. Flashing incandescent Christmas lights take advantage of this effect. Some flasher bulbs interrupt power when heated, while other twinkle/sparkle mini-bulbs momentarily shunt current around the filament.

Thermal switches are part of the normal operation of older fluorescent light fixtures, where they are the major part of the starter module.

GE trademarked the name "Guardette" for the thermal protection switches used on their refrigeration compressors.

Thermal switches on microprocessors often stop only the fetching of instructions to execute, reducing the clock rate to zero until a lower temperature is reached, while maintaining power to the cache to prevent data loss (although a second switch, with a higher triggering temperature, usually turns off even the cache and forces the computer to reboot). This mitigates the impact of programs resembling power viruses on the processor's longevity, while still accommodating their possible legitimate uses; it can also make overclocking possible with less risk.

Manual reset

Some thermal switches must be reset manually after they have been tripped. This design is used when an automatic and unattended restart would create a hazardous condition, such as sudden startup of a powerful motor without warning. These types of thermal cutouts are usually reset by pressing a push-button by hand or with a special tool.

Source of the article : Wikipedia



EmoticonEmoticon

 

Start typing and press Enter to search